LR-retaining walls (without heel)
3D viewer
Technical drawing

LR-retaining walls (without heel) - LR050S

The LR retaining wall without heel has been specially developed for heavier (R=retaining) load applications in civil engineering and is available in a number of different... Read more

Description

The LR retaining wall without heel has been specially developed for heavier (R=retaining) load applications in civil engineering and is available in a number of different lengths. The LR retaining wall is always 150 mm thick at the top edge and is equipped with a special coupling slat recess. As a result, this retaining wall is ideal for placement at different heights.
* This retaining wall does not have a heel and is therefore perfect for use at a plot boundary.
* The retaining wall has a total net height, making it easy to measure and place.
* The foot side is the load-bearing side.
* The perpendicular rear side results in an attractive, straight and dimensionally stable retaining wall following placement.
* The robust design makes this retaining wall ideal for demanding environmental (chemical) applications.
* This retaining wall has a life of at least 100 years.

Specifications.

Concrete mixture 2nd generation self-compacting C60/75 Reinforcement steel B500
Weight 1109kg (L = 3995mm) Concrete cover 45mm
Dimensional tolerance +/- 5mm Concrete suface finish All visible sides class A (B1 on request)
Design life 100 years Product warranty 10 years
Environmental class XA3, XC4, XD3, XS3, XF4 Hoisting device None, to be placed with clamp

Extra options

Partitioning wall connector
View this option
U wall connector
View this option
Bevelling
View this option
Standard corner solution
View this option
Shortening and other adaptations
View this option
Close